ALLSHENG ALLSHENG
Ecos-Gene 6400
  • Ecos-Gene 6400
Automated Nucleic Acid Extraction and PCR System — Ecos-Gene 6400

Ecos-Gene 6400 automated nucleic acid extraction and PCR system integrates all functional divisions of PCR detection laboratory. It is a one-stop workstation that integrates the functions of information input, reagent dispensing, sample preparation, nucleic acid extraction based on magnetic bead method, system construction, cover centrifuge, qPCR detection, result analysis, and etc. The whole process from sample loading to report output does not require manual intervention. It can realize sample in and result out and provide you with a new solution for molecular diagnosis.

  • ALLSHENG ALLSHENG
    Features
  • ALLSHENG ALLSHENG
    Technical parameter
  • ALLSHENG ALLSHENG
    Order information

官网详情页-Ecos-Gene 6400.jpg

  • Model
    Ecos-Gene 6400
  • Throughput
    1~64
  • Sample tube
    Support the original tube loading of sampling tube / blood sampling tube
  • Extraction temperature performance
    Heating range 37 °C~120 °C
  • Extraction temperature performance
    Temperature accuracy ±0.5 °C
  • Extraction performance
    Extraction time: according to the reagent solution, generally 25~30 min / time
  • Extraction performance
    Extraction uniformity CV≤5%
  • PCR amplification
    Average heating rate: block 50 °C~95 °C: ≥5 °C/s
  • PCR amplification
    Maximum heating rate: block 50 °C~95 °C: ≥10 °C/s
  • PCR amplification
    Average cooling rate: block 95 °C~50 °C: ≥5 °C/s
  • PCR amplification
    Maximum cooling rate: block 95 °C~50 °C: ≥8 °C/s
  • PCR amplification
    Temperature accuracy ≤±0.2 °C
  • PCR amplification
    Block temperature control accuracy ≤±0.2 °C 55 °C
  • PCR thermo lid
    Temperature range RT. +5 °C~105 °C
  • PCR thermo lid
    Temperature control accuracy ±0.5 °C
  • Detection block
    PCR reaction system 15~100 μL
  • Detection block
    Fluorescence detection channel: 5 channel
  • Detection block
    Applicable fluorescent dyes: FAM / HEX / ROX / CY5 / CY5.5, etc.
  • Detection block
    PCR kinetic range 1~10^10 Copies/μL
  • Detection block
    Detection time: according to the reagent solution, generally 35~50 min / time
  • UV sterilization
    One UV sterilization lamp is set in the sample preparation area, buffer area and analysis area respectively, which can be controlled independently
  • HEPA
    An independent HEPA component is set in the sample preparation area and analysis area respectively
  • Software operation
    Windows system software, supporting personalized function customization
  • Instrument port
    1×B-USB port and 1×Ethernet port
  • Information management
    Support external code scanner, which can input sample / reagent information; expandable LIS system connection; expandable cloud database connection
  • Code
    Description
  • AS29010-00
    Ecos-Gene 6400 automated nucleic acid extraction and PCR system
  • AS29011-01
    Magnetic rod sleeve
  • AS29011-02
    PCR tube caps
  • AS29011-03
    96 deepwell plate
  • AS-TT-200-N
    200 μL, Allsheng tip, transparent, boxed
  • AS-TT-200-NL
    200 μL, Allsheng tip, transparent, boxed, low adsorption
  • AS-TT-200-NS
    200 μL, Allsheng tip, transparent, boxed, sterile
  • AS-TT-200-NSL
    200 μL, Allsheng tip, transparent, boxed, sterile, low adsorption
  • AS-TTF-200-NS
    200 μL, Allsheng tip, transparent, boxed, sterile, filter element
  • AS-TTF-200-NSL
    200 μL, Allsheng tip, transparent, boxed, sterile, filter element, low adsorption
  • AS-TT-1000-N
    1000 μL, Allsheng tip, transparent, boxed
  • AS-TT-1000-NL
    1000 μL, Allsheng tip, transparent, boxed, low adsorption
  • AS-TT-1000-NS
    1000 μL, Allsheng tip, transparent, boxed, sterile
  • AS-TT-1000-NSL
    1000 μL, Allsheng tip, transparent, boxed, sterile, low adsorption
  • AS-TTF-1000-NS
    1000 μL, Allsheng tip, transparent, boxed, sterile, filter element
  • AS-TTF-1000-NSL
    1000 μL, Allsheng tip, transparent, boxed, sterile, filter element, low adsorption
ALLSHENG