Features

奥盛仪器
01 Large Volume Extraction to Meet Special Needs
The maximum reaction system of the sample library is 5 / 10 mL, which can meet the needs of cfDNA extraction.
The elution well is eluted in a small volume to meet the nucleic acid concentration requirements.
奥盛仪器
02 High-Precision Pipetting
Dual-channel pipetting design, 1×(50-5000 μL), suitable for 1 mL / 5 mL pipettor and 1×(1-200 μL), suitable for 200 μL pipettor.
The pipettor’s pressure detection technology can not only detect the height of the liquid level, but also empty suction, residual liquid volume and blockage detection.
Detailed pipetting parameter settings for different liquids can effectively improve the accuracy.
奥盛仪器
03 Methylation Conversion Special Functional Modules
Module temperature control range 4 °C~105 °C.
In order to meet the methylation requirements, 2400M adds a temperature control module to realize multistage temperature change.
Thermo lid design can prevent water vapor from the reaction solution from condensing on the tube cap, maintaining the volume stability of the reaction system, ensuring the accuracy of experimental results.
奥盛仪器
04 Easy-to-Learn Operating Software
Graphical user interface, program editing can be completed without complicated operations.
Built-in comprehensive libraries of consumable arriers and liquids to reduce customer program matching time.
Users can simply select according to their needs to complete the whole process of pipetting, extraction, and PCR / qPCR setup.
ModelAuto-Pure 2400M
FunctionAutomatic pipette samples and reagents, extract nucleic acid and set-up PCR systems
Information managementSupport external USB scanner, barcode scanning function, automatic scanning function
Pipetting principleAir displacement pipetting technology
PipettorOne 5000 μL pipettor, one 200 μL pipettor
Pipetting range (μL)1~5000 μL
TipsAllsheng tips, and other tips compatible with this instrument
Liquid detectionPressure detection: liquid level detection, tip clogging detection and residual liquid detection
Samples per run1~24
Extraction processing volume50~10000 μL
Extraction uniformityCV ≤5%
Single sample consumableSupport
Extraction temperature controlElution, lysis temperature control: RT.~120 °C
Temperature control block°C~105 °C
UV sterilizationSeparate UV lamp: extraction area, pipetting area and waste container area
FilterEquipped with three HEPA filters
Instrument portUSB port
Power supply220 V, 8 A, 50 / 60 Hz
PowerStandby 30 W, maximum 600 W
Noise≤60 dB
Net weight130 kg


CodeProduct description
AS-17220-00Auto-Pure 2400M
AS-17151-0110 mL cartridge
AS-17151-02Magnetic rod comb
AS-17151-035 mL cartridge
AS-17151-052 mL storage tube
AS-TT-200-N200 μL tip (transparent, boxed)
AS-TT-1000-N1000 μL tip (transparent, boxed)
AS-TT-5000C-NL-LB5000 μL conductive tip (conductive, SBS box, low adsorption)
AS-17202-015 mL sample tube
AS-17202-021.5 mL centrifuge tube
AS-17202-032 mL centrifuge tube
AS-17202-047 mL centrifuge tube
AS-17202-068-strip PCR tube (0.2 mL)
AS-17202-0715 mL wide-mouth plastic bottle
AS-17202-08100 mL reservoir
AS-17202-09Medical waste packaging bag
AS-17202-104000 μL tip
RS-HSCF0101Nucleic acid extraction or purification reagents (1 mL) 10 T, 24 T, 50 T, 100 T
RS-HSCF0102Nucleic acid extraction or purification reagents (2 mL) 24 T, 50 T
RS-HSCF0104Nucleic acid extraction or purification reagents (4 mL) 24 T, 50 T