Features
-
4.3-inch touch screen, easy to use.
Temperature and protocols can be edited and saved according to different reagent requirements.
Short operation time: 15~30 min per run.
High yield of nucleic acid with low magnetic bead loss and good repeatability of results.
UV sterilization, avoid cross-contamination.
Open system which can apply to different magnetic bead extraction reagent.
APP software (Android system) which can monitor the system in real time through mobile device.
With PC software and APP, edit, set and manage programs more easily.
Screw rod design which guarantee high operating accuracy; large guide rail design makes the structure more reliable.
With QR code identification function, special reagent can be recognized, no need to program or obtain protocols.
Open instrument parameter settings, can set freely: mixing speed, magnetic absorption, release, cooling fan and other functions.
Small volume, suitable for extraction on site.
Up to 16×1 mL samples can be processed in one run, which is an ideal choice for automatic extraction in small laboratories.
PCR Detection General Solution
| Model | Auto-Pure 16A |
| Throughput | 1~16 |
| Process volume | 50~1000 μL |
| Consumable | 96 deepwell plate + magnetic rod comb |
| Purification accuracy | 100 copy sample positive rate >95 % |
| Stability | CV <5 % |
| Lysis temperature | RT.~120 °C |
| Elution temperature | RT.~120 °C |
| Collection efficiency | >95 % |
| Operation | 4.3-inch touch screen, 3 shortcut keys, external mouse |
| Storage capacity | Preset 6 programs, max store 100 programs |
| Software | PC software, APP software, program editing, easier management |
| Extension interface | Standard USB, Ethernet port, wifi |
| Lighting | Yes |
| Pollution control | UV sterilization |
| Exhaust | Fan |
| Data storage | Built-in SD card |
| Power supply | 300 W |
| Dimension (W×D×H) | 340 mm×350 mm×410 mm |
| Weight | 18 kg |
| Code | Product description |
| AS-17140-00 | Auto-Pure 16A nucleic acid purification system |
| AS-17031-01 | 96 deepwell plate for Auto-Pure 16A |
| AS-17031-02 | Magnetic rod comb for Auto-Pure 16A |
Related Products
Selection Guide
Model | ||||
Throughput | 1~16 | 1~16 | 1~32 | 1~32 |
Processing volume | 20~1000 μL | 50~5000 μL | 30~1000 μL | 50~1000 μL |
Consumables | 8-tip comb 96 deepwell plate / single cartridge | 96 deepwell plate + magnetic rod comb | 96 deepwell plate + magnetic rod comb | 96 deepwell plate + magnetic rod comb |
Other functions | Can be connected to an app for use | - | Scanning function | - |